FLRY-B Cable
Single Core Unshielded Cable

CONSTRUCTION :
  • Stranded or Solid
  • Bare or Tinned Copper
  • PVC Insulation

CHARACTERISTICS :
  • Temperature Range: -40° C to +105° C

APPLICATION :
  • FLRY - B is a PVC Automotive Cable with Type B Conductor and thin
    wall insulation used for automotive batteries and harnesses.

Specifications of FLRY-A Cable :

Write to Us

Conductor Construction Insulation Wall thickness min. Cable
Nominal Cross- Section No. of Strands Diameter of Single Wire max. Diameter of Conductor max. Electrical Resistance at 20° C Overall Diameter Weight
bare/tinned min. bare/tinned max. Nom. Limit Tolerance Approx.
mm

nos.

mm mm

mΩ/m

mΩ/m mm mm mm kg/km
0.35 12

0.21

0.9

47.8/-

42.0/54.5

0.20

1.4

-0.2

4.5

0.5

16

0.21

1.0

34.1/-

37.1/38.2

0.22

1.6

-0.2

6.6

0.75

24

0.21

1.2

22.7/-

24.7/25.4

0.24

1.9

-0.2

9

1 32

0.21

1.35

17.0/-

18.5/19.1

0.24

2.1

-0.2

11

1.5

30

1.26

1.7

11.7/-

12.7/13.0

0.24

2.4

-0.2

16

2 30

0.31

2.0

8.5/-

9.42/9.69

0.28

2.8

-0.3

22.5

2.5

50

0.26

2.2

7.0/-

7.6/7.8

0.28

3.0

-0.3 26
3 45

0.31

2.4

5.8/-

6.15/6.36

0.28

3.2

-0.3

33.5

4 56

0.31

2.75

4.32/-

4.7/4.8

0.32

3.7

-0.3

42
6 84

0.31

3.3

2.85/-

3.1/3.2

0.32

4.3

-0.3

61

10 80

0.41

4.5

-/-

1.82/1.85

0.48

6.0

-0.5

108

16

126

0.41

6.3

-/-

1.15/1.18

0.52

7.9

-0.6

170

25 196

0.41

7.8

-/-

0.743/0.757

0.52

9.4

-0.8

265


*Normal value, tolerance of number of strands: ± 5% (≥ 6.0 mm2).